Prøv at konfigurer følgende setup på en Juniper SRX: BGP Demo Setup

Opgave

Grundlæggende

  • Konfigurer IP Adresser på alle Logical Tunnel interfaces
    • De skal ligge i 10.255.0.X/30 netværkene
    • LT interfacet skal have samme unit nummer som .4 oktet i op adressen(10.255.0.2 = lt-0/0/0.2)

Kontroller at de virtuelle routere kan pinge hinanden.

root@SRX240> <input>ping 10.255.0.2 routing-instance PE5</input>
PING 10.255.0.2 (10.255.0.2): 56 data bytes
<notice>64 bytes from 10.255.0.2: icmp_seq=0 ttl=64 time=1.132 ms
64 bytes from 10.255.0.2: icmp_seq=1 ttl=64 time=1.068 ms
64 bytes from 10.255.0.2: icmp_seq=2 ttl=64 time=1.012 ms</notice>
^C
--- 10.255.0.2 ping statistics ---
3 packets transmitted, 3 packets received, 0% packet loss
round-trip min/avg/max/stddev = 1.012/1.071/1.132/0.049 ms