Udstyr

  • 5 stk. Lenovo ThinkCenter (C01, C04, C05, C06, C17)
  • 2950

Setup

C01 bliver master server, med apt-cacher til installation og PXE netinstallation server. Den skal også have MRTG og nagios.

  • C01 sidder i Gi0/2
  • C04 sidder i Fa0/1
  • C05 sidder i Fa0/2
  • C06 sidder i Fa0/3
  • C17 sidder i Fa0/4

2950

enable password cisco
!
interface range fa 0/1 - 24
 switchport mode access
 switchport access vlan 2
 spanning-tree portfast
!
interface range gi 0/1 - 2
 switchport mode access
 switchport access vlan 2
 spanning-tree portfast
!
interface Vlan2
 ip address 10.1.2.50 255.255.255.0
!
snmp-server community public RO
!
line con 0
line vty 0 4
 no login
line vty 5 15
 no login

C01